Scope of application

The PQFM active filter is used to filter harmonic currents, reactive current compensation and load current balancing between the phases. phases. The filter is preferably used in industrial networks with non-linear three-phase consumers (frequency converters, UPS systems, etc.). used.

Description

The PQFM active filter is connected in parallel to the mains. From the harmonic currents are fed into the supply network from the active filter. which are in phase opposition to the harmonic currents of the load. load. At the connection point, the selected At the connection point, the selected harmonics are reduced to at least 97% of the filter's nominal current. Each active filter consists of a basic unit and up to 7 extension units. extension units. Adjacent nominal current groups may be combined The distance between the smallest and the largest filter unit may be max. be max. one nominal current group.

Advantages

Operational safety, cost savings

Compliance with EMC directives

Sustainability











Schutzart: IP 30, Nennspannung 380 - 415 V










Nennstrom
A

Bestellbezeichnung Absicherung (bauseits)
A

Maße
(B x T x H)
mm
Gewicht

ca. kg
Artikel-
Nummer











Grundeinheit
















30

PQFS-M03-IP30 50
585 x 310 x 700 120 NQ2130
45

PQFS-M04-IP30 63
585 x 310 x 700 120 NQ2131
60

PQFS-M06-IP30 80
585 x 310 x 700 120 NQ2132
70

PQFS-M07-IP30 100
585 x 310 x 700 120 NQ2133
80

PQFS-M08-IP30 100
585 x 310 x 700 120 NQ2134
90

PQFS-M09-IP30 125
585 x 310 x 700 120 NQ2135
100

PQFS-M10-IP30 125
585 x 310 x 700 120 NQ2136
120

PQFS-M12-IP30 160
585 x 310 x 700 120 NQ2137










Erweiterungseinheit
















45

PQFS-S04-IP30 63
585 x 310 x 700 120 NQ2141
60

PQFS-S06-IP30 80
585 x 310 x 700 120 NQ2142
70

PQFS-S07-IP30 100
585 x 310 x 700 120 NQ2143
80

PQFS-S08-IP30 100
585 x 310 x 700 120 NQ2144
90

PQFS-S09-IP30 125
585 x 310 x 700 120 NQ2145
100

PQFS-S10-IP30 125
585 x 310 x 700 120 NQ2146
120

PQFS-S12-IP30 160
585 x 310 x 700 120 NQ2147




















The new PQFS filters are not compatible with the old PQFS filters. filters (delivered until 06/2010).
Existing installations may have to be extended with a master. be extended.
PQFS filters are not suitable for mains with commutations in the mains voltage.
PQFS filters consist of max. 4 wall-mounted cabinets of the same rated current group (1 x master + 3 x slave).
Preferred sizes other than those given here can easily be calculated yourself.
Accessories on request.